1 | PIR Ready VT76xxW Series-Installation Guide
CONTENTS
Installation 2
Location 2
Installation 2
Theory of operation 3
Features overview 3
Model Chart 5
Network ready 5
Terminal, Identification and Function 6
Wiring 6
Screw terminal arrangement 7
Main outputs wiring 7
Typical applications 7
Remote sensor accessories 8
Configuring and Status Display Instructions 11
Status display 12
User Interface 13
User configuring instructions menu 13
Local keypad interface 14
Occupied setpoints adjustments 15
Installer Configuration Parameter Menu 22
Troubleshooting guide 32
All models 32
Specifications 34
Drawing & Dimensions 35
PIR Ready VT7600W Series
With & Without Local Schedule
Water Source Heat Pump
Terminal Equipment Controllers
Installation Guide
For Commercial HVAC Applications
May 3
rd
, 2012 / 028-0355-R4
Zobrazit stránku 0
1 2 3 4 5 6 ... 34 35

Shrnutí obsahu

Strany 1 - Installation Guide

1 | PIR Ready VT76xxW Series-Installation Guide CONTENTS Installation 2 Location 2 Installation 2 Theory of operation 3 Features overview

Strany 2 - INSTALLATION

10 | PIR Ready VT76xxW Series-Installation Guide -28 -18 151.6239 -8 18 48.7042 12 54 17.9636 32 90 7.4182 52 126 3.3568 -27 -17 142.7211 -7 19

Strany 3 - THEORY OF OPERATION

11 | PIR Ready VT76xxW Series-Installation Guide WIRING S2000D1000, S2060A1000 AND S2020E1000 Remote wiring 1 sensor Rem

Strany 4

12 | PIR Ready VT76xxW Series-Installation Guide Status display The Terminal Equipment Controller features a two-line, eight-character display. There

Strany 5 - MODEL CHART

13 | PIR Ready VT76xxW Series-Installation Guide Frost ON Indicates that the heating is energized by the low limit frost protection room temperatur

Strany 6 - Wiring

14 | PIR Ready VT76xxW Series-Installation Guide If the user pauses at any given time during configuring, Auto Help text is displayed to help and gui

Strany 7 - TYPICAL APPLICATIONS

15 | PIR Ready VT76xxW Series-Installation Guide Sequence of user menu: OVERRIDE RESUME TEMPERATURE SETPOINTS SYSTEM MODE SETTING FAN MODE SETTIN

Strany 8 - Remote sensor accessories

16 | PIR Ready VT76xxW Series-Installation Guide A) Override an unoccupied period Override schd Y/N This menu will appear only when the Terminal E

Strany 9

17 | PIR Ready VT76xxW Series-Installation Guide Local changes to the heating or cooling setpoints made by the user directly using the up or down arr

Strany 10

18 | PIR Ready VT76xxW Series-Installation Guide F) Schedule set (2 events) Scheduling can have 2 or 4 events per day. This is set in the configurati

Strany 11 - User menu flow chart:

19 | PIR Ready VT76xxW Series-Installation Guide Ex. #2 Commercial building which is occupied all weekend Event Period #1 - Event #1 Period #1 - Even

Strany 12 - Status display

2 | PIR Ready VT76xxW Series-Installation Guide INSTALLATION Remove the security screw on the bottom of Terminal Equipment Controller cover.  O

Strany 13 - USER INTERFACE

20 | PIR Ready VT76xxW Series-Installation Guide Ex. #1 Four event retail establishment schedule Event Period 1 - Event 1 Period 1 - Event 2 Period 2

Strany 14 - Local keypad interface

21 | PIR Ready VT76xxW Series-Installation Guide H) Clock/Day Settings Clock set Y/N This section of the menu permits the user to set the time

Strany 15 - Sequence of user menu:

22 | PIR Ready VT76xxW Series-Installation Guide Schedule uno hold Hold permanent unoccupied forces the Terminal Equipment Controller into a permane

Strany 16

23 | PIR Ready VT76xxW Series-Installation Guide CONFIGURATION PARAMETERS DEFAULT VALUE SIGNIFICANCE AND ADJUSTMENTS PswrdSet Configuration paramete

Strany 17

24 | PIR Ready VT76xxW Series-Installation Guide Channel Channel selection Default value = 10 Range is: 10 to 26 Conditional parameter to Wireless m

Strany 18

25 | PIR Ready VT76xxW Series-Installation Guide DI 1 Digital input no.1 configuration Open contact input = function not energized Closed contact inp

Strany 19

26 | PIR Ready VT76xxW Series-Installation Guide lockout Keypad lockout levels Default value = 0 No lock 0 = No lock 1 = Low level 2 = High level USE

Strany 20

27 | PIR Ready VT76xxW Series-Installation Guide Pband Proportional Band setting Default value 2 = 2.0 °F ( 0.6 °C ) Adjust the proportional band use

Strany 21 - (Network Ready) Terminal

28 | PIR Ready VT76xxW Series-Installation Guide deadband Minimum deadband Default value = 2.0 °F ( 1.1 °C ) Minimum deadband value between the heati

Strany 22

29 | PIR Ready VT76xxW Series-Installation Guide HP stage Number of heatpump stages Default value = 2 stages Will revert the operation of 2 st

Strany 23

3 | PIR Ready VT76xxW Series-Installation Guide 10. Insert each wire according to wiring diagram. 11. Gently push excess wiring back into hole (fig

Strany 24

30 | PIR Ready VT76xxW Series-Installation Guide aux cont Auxiliary contact configuration Default value = N.O. normally open This contact can be u

Strany 25

31 | PIR Ready VT76xxW Series-Installation Guide Dhu set Dehumidification setpoint Default is 50 % RH Used only if dehumidification sequence is enab

Strany 26

32 | PIR Ready VT76xxW Series-Installation Guide TROUBLESHOOTING GUIDE All models Symptom Possible Cause Corrective Action No display on the Termina

Strany 27

33 | PIR Ready VT76xxW Series-Installation Guide Wiring error 1. Start the Fan by forcing the Fan ON mode 2. Put a jumper across terminals RC & Y

Strany 28

34 | PIR Ready VT76xxW Series-Installation Guide SPECIFICATIONS Terminal Equipment Controller power requirements: Operating conditions: Storage con

Strany 29

35 | PIR Ready VT76xxW Series-Installation Guide DRAWING & DIMENSIONS Viconics Technologies Inc. Tel.: Fax: Toll free:www.

Strany 30

4 | PIR Ready VT76xxW Series-Installation Guide  Remote discharge air temperature sensor input for monitoring purpose  Remote water temperature s

Strany 31

5 | PIR Ready VT76xxW Series-Installation Guide MODEL CHART Network ready  All Viconics VT7600 series Terminal Equipment Controllers are design

Strany 32 - TROUBLESHOOTING GUIDE

6 | PIR Ready VT76xxW Series-Installation Guide TERMINAL, IDENTIFICATION AND FUNCTION Wiring Water Source Heat Pump Part Number VT7652W VT7600W Sche

Strany 33

7 | PIR Ready VT76xxW Series-Installation Guide Screw terminal arrangement Main outputs wiring Wiring notes: Note 1: Electromechanical contacts

Strany 34 - SPECIFICATIONS

8 | PIR Ready VT76xxW Series-Installation Guide Remote sensor accessories MODEL NO. DESCRIPTION S3010W1000 Wall mounted temperature sensor S3020W100

Strany 35 - DRAWING & DIMENSIONS

9 | PIR Ready VT76xxW Series-Installation Guide WIRING EXAMPLES OF 2 REMOTE ROOM SENSORS FOR AVERAGING APPLICATIONS: WIRING EXAMPLES OF 3 RE